The
increased
modern
requirements for the
assessment of the presented material objects
in the work of forensic medical experts is a subject
of
this
research. For this purpose, many different physical and chemical
methods of instrumental research are used. In this case, the method of
non-strict analogy is usually used, where the direct feature under study isn’t
related to a similar one.
The
research using this method often
provides the results of a
probabilistic nature. A non-strict analogy
is the case
of
the dependence between similar and transferable signs is thought
to be necessary only with a greater or lesser degree of probability. In this
case, if we find a sign of similarity in another object, we can only conclude
in a logically weakened form that the transferred attribute belongs to the
latter [1].
Nevertheless, forensic medical examination doesn’t allow
using the
methods that
give only probabilistic results. Therefore, in modern forensic medicine,
statistical analysis data are used to determine diagnostic signs characteristic
of specific types of traumatic effects [2-4].
Currently, modern computer technologies have become widespread in
biomechanics and forensic medicine. The
area takes advantage
of
three-dimensional software modeling of objects, mathematical modeling, etc.,
which corresponds to the general direction of high-tech research methods in
medicine. Methods and software products that allow visualizing physical
processes are becoming increasingly widespread. To solve expert questions,
the
data from physics and
mathematics are used, concepts and laws of mechanics of a deformed solid, the
theory of cutting materials, etc. are used.
Thus, the method of finite element analysis (FEA),
that is conventionally
used
for
solving problems of
deformable solid mechanics, electro-and magnetostatics, gas dynamics, as well
as other fields of physics, is
also
used to assess the energy distribution in solid tissues. Finite
element analysis is based on the use of the mathematical finite element method.
The finite element method (FEM) is a numerical method for solving
partial differential equations, as well as integral equations arising in
solving problems of applied physics, which has been used since the 1950s. At
this time, the method was not widely used due to the low level of computer
technology. With the development of technical capabilities, the possibilities
of using the method have expanded. Currently, the method is widely used to
solve problems of deformable solid mechanics in the science of "resistance
of materials", heat transfer, hydro-gas dynamics and electrodynamics [6,
7].
In modern conditions, it has become impossible to use tracological
studies on living tissues, which leads to doubts about the reliability of the
experimental results and the value of the study as a whole. A promising method
of research under these conditions is the method of mathematical modeling of
the destruction of biological tissues, considering the mechanical properties of
biological tissues and boundary conditions [8-12, 15]. The purpose of this work
was to analyze the possibility of using the finite element method in modern conditions
to solve problems in the study of stab injuries of ribs.
The rib is a helically curved irregular elliptical cylinder
consisting of spongy bone tissue with a thin layer of compact bone tissue on
the outer surface (Fig. 1).
Fig. 1. Photo of a native cleaned edge. The arrow indicates the
front flat part of the rib.
The
rib preparations
were
carried out in the
following way: bones
were degreased in an aqueous solution of sodium
laurate, then dried for 2-3 days.
In some cases, graphite powder was contrasted, which was applied
to the edges of the damage to eliminate glare during photography and
microscopy.
The samples
were
also degreased and the damage surface was shaded.
To reduce the reflection of light during photographing and
microscopy of stab injuries, as well as to increase the contrast of individual
elements of the bone profile, the surface was shaded. The edges of the bone
injuries were treated with a 5% solution of iodine and a solution of brilliant
green (2%), then fine soot was sprayed on the surface of the damage.
Next, the bone macro-preparations were examined using a binocular
magnifier and an MBS-10 stereomicroscope.
In full-scale experimental studies on biomanequins, morphological
signs of damage to a human rib were studied under the impact of a
piercing-cutting object under conditions of translational movement of a hand
with a knife at a speed of up to 10 m/s along the flat part of the anterior
third of the fixed rib with the orientation of the blade axis of the knife
blade along the axis of the bone.
In experimental studies, the data of the knife blade were used:
the depth of immersion of the blade was 54 mm; the width of the blade at this
level of immersion was 17-17.5 mm; the thickness of the blade in the middle
part of the butt was 1.2 mm; the knife had a pronounced tip zone (Fig. 2) [13,
16].
Fig. 2. Photo of
the
knife used in field experiments.
We used FEM to
visualize and
find out the possibilities
of mathematical modeling of the process of forming a rib injury
that occurs at the injection point.
For
mathematical modeling, we
created
the
three-dimensional graphic models of the blade of a
piercing-cutting trace-forming object and a trace-receiving material-bone
in the ANSYS EXPLICIT DYNAMICS 2020 R2[17] software package.
ANSYS is one of the popular software environments for finite element
analysis, for solving linear and nonlinear problems of deformable solid
mechanics, developed by the American company Ansys inc. and used for the
analysis of the destruction of solids, including in forensic medicine.
The biophysical parameters of the rib were set as averaged,
obtained during the study of various sections of the rib. The blade of the
knife is modeled according to the data of a full-scale experiment made of steel
with standard parameters [18]. A model of the rib segment with the physical parameters
of the spongy bone was constructed: density 200 kg/m3, Young's
modulus 17000 MPa, yield strength 110 MPa [19]. The finite element grid is
generated in an automated mode by Solid type finite elements, which are used to
simulate a volumetric stress-strain state. The restriction is set for the
movement of the bone and the knife blade perpendicular to the plane of symmetry
of the edge. The impact action of the knife blade in the model is modeled
perpendicular to the edge axis with a force of 5000 N and a speed of 10000
mm/s, while its movements are limited in all directions except vertical, with
the application of forces on the upper surface of the blade model. The rib was
regarded by us as a beam with sealing of the ends (cantilever attachment) (Fig.
3).
Fig. 3. The scheme of the support of the rib as a beam with the
sealing of the ends – a cantilever attachment.
In the field experiments conducted along the axis of the rib,
through-through injuries repeated the shape of a one-sided sharp blade and
displayed its cross-sectional shape.
A bone tissue defect with edges formed by crushed bone tissue was
found in the injection zone. The shape of the defect at the injection point
approached an isosceles triangle and corresponded to the size of the zone of
action of the experimental knife tip (Fig. 4).
Fig. 4. Type of stab injury to the rib in a full-scale experiment
(view from the side of the external bone plate).
Smooth edges of bone tissue damage were recorded in the
continuation of the crumpling zone. The smooth, linear separation zone, the
parallelism of the opposite edges to each other in all planes testified to the
effect of the cutting edge of the blade on bone.
Three zones
are distinguished in the damage profilogram (Fig. 5):
Fig. 5. Morphology of a stab injury to a rib: a-view from the side
of the external bone plate, b-profile of the injury in the bone. The lines mark
the areas where the edges and walls of the damage correspond.
1.
In the zone of action of the
knife tip zone, a longitudinal stratification of bone tissue, a crumpling
(flattening in the transverse direction) of the cells of the spongy substance
of the bone is recorded. There is a transfer of fragments of the external bone
plate deep into the damage. According to the action of the edge of the butt of
the knife blade, the area of grinding (erasure, flattening) of the compact and
spongy substance of the bone tissue is clearly recorded with the naked eye.
This correspondence is explained by a single mechanism of damage formation –
end cutting; a profile study of the walls of the wound canal of the injury
allows you to clearly determine the point of injection – the zone of action of
the tip of the knife blade. The nature of the deformation of the outer bone
plate and the cells of the spongy substance allows us to assess the direction
of the impact of the blade tip and the metric characteristics of the blade tip.
The transition from the first section to the second was recorded in the form of
an arc-shaped bend of the edge and the wall of the damage (Fig. 6);
Fig. 6. Visualization of the injection point of a stab injury to
the rib
2. In the area of the blade action (cutting itself), there is no
macroscopically deformed cells of the spongy bone tissue and an even plane of
separation is determined;
3. When examining the area of the zone of action of the blade tip
of the knife, the separation plane is clearly defined, which was presented in
the form of slightly protruding and sinking smooth wavy sections. The most
protruding areas of the bone had a pronounced shine – this indicated that the
surface was sanded from the action of the blade sharpening fields (Fig. 7).
This feature corresponds to the data of the theory of cutting materials: when
cutting longitudinally, the blade forms a crack in front of it, then the
sharpening fields acting on the walls provide immersion of the blade wedge.
Fig. 7. The cutting area on the wall of the stab injury of the
rib: small fragments of bone tissue are visualized (a - general plan of the
wall of the stab injury, b- micrograph of the zone of the leading crack).
As a result of mathematical modeling by the method of finite
element analysis, the
following
results are obtained:
1. When exposed to the blade of a knife, a critical load of bone
tissue occurs with its destruction and the formation of a through damage. Figure
8 shows the last stage of modeling the through penetration of the knife blade
along the rib axis with the distribution of equivalent stresses along the Mises
in various parts of the bone wound – the maximum equivalent stresses occur in
the zone of action of the knife tip at the border with the spine part in the
amount of 223.3 MPa. displacement and deformation of finite elements in the
outer surface along the axis of action of the blade of the knife model.
Fig. 8 Mathematical model of the formation of rib damage under the
action of a piercing-cutting object. Equivalent Mises stresses.
2. When rib is damaged by the blade of a knife blade, bone
fragments are displaced in the direction and in the zone of action of the knife
blade tip zone with the maximum concentration of equivalent stresses at the
edge of the edge zone (114.16 MPa), which indicates a change in the end type of
cutting to the longitudinal one, which is shown in Fig. 9.
Fig. 9 Mathematical model of rib formation of damage under the
action of a piercing-cutting object. Equivalent Mises stresses. The arrow
indicates the place of concentration of equivalent stresses during cutting.
3. When analyzing shear stresses in the area of a bone wound, it
was found that the maximum concentration of equivalent stresses of bone tissue
at the boundary of the action of the tip zone is formed mainly due to shear
deformation and is 36.378 MPa (Fig. 10).
Fig. 10 Mathematical model of rib formation damage under the
action of a piercing-cutting object. Shear stresses. The arrow indicates the
location of the shear stress concentration.
●
When comparing the results of
field experiments and finite element analysis of the destruction of the rib
from the piercing-cutting action of the knife blade, it was found full
correspondence of the location of the bone wound zones and morphological features
in the damage profilograms (Fig. 11):
●
The zone of action of the
knife tip (the injection point) is detected. It
is manifested by the area
of compression, deformation and displacement of the elements of the outer
plates into the damage with the maximum concentration of equivalent stresses;
●
In the area of action of the
knife blade, there is a crumpling and displacement of the finite elements
transversely to the axis of action of the knife blade with a minimum
concentration of equivalent stresses;
●
At the boundary of these two
zones, a surge of equivalent stresses due to shear deformation is determined,
indicating a change in the end type of cutting to the longitudinal and the end
of the zone of the blade edge of the knife.
Fig. 11. Comparison of the profilogram of experimental full-scale
damage (left) and the profile of the results of finite element modeling
(right). The similarity of the location and morphology of the bone damage zones
is noted.
Thus, the
mathematica model traces
all the main
morphological signs of the native experimental stab injury of the rib. As a
result of a comparative study, we were able to establish the possibility of
using the method of finite element analysis for the study of stab-cut injuries
and justified the morphological basis of the transition point of
end-to-longitudinal cutting at the border of the action zone of the knife edge.
Thus, the use of mathematical modeling of FEM allows
visualizing
and
predicting
the stresses
that arise in the trace-receiving material when exposed to the pronounced zone
of the blade tip of a piercing-cutting object. The
results of
computer simulation are confirmed by
the results of original field experiments [13].
It should be noted that at the moment, due to the weak
introduction of FEM into expert practice, the authors of the article cannot
assess how reliably this method will allow predicting the process of destruction
of biological objects under various types of mechanical impact, as well as to
assess the scope of practical use and demand for mathematical modeling of FEM
in forensic medicine. In forensic medicine, there are no methods for
mathematical analysis and modeling of the process of destruction of biological
objects as a result of the influence of mechanical factors, so we consider the
use of FEM to be the most promising at the moment.
Data from foreign sources on the use of FEM in modeling the fall,
the behavior of implants in bone tissue, and skin destruction suggest a high
efficiency of the method [11, 12, 14].
The use of
FEM in forensic medicine in the future
allows
reliable
prediction of
the process of
destruction of biological objects under various types of mechanical impact with
further visualization, and in the future, it is possible to solve the inverse
problem — to speak about the tracological properties of the traumatic tool
based on the morphological picture of destruction.
1.
Kirillov V.I., Starchenko A.A.
Logika: Uchebnik dlya yuridicheskih vuzov. — Izd. 5-e, pererab. i dop. — M.:
YUrist", 1999. — 256 p. [in Russian]
2.
Leonov S.V., Krupin K.N.
Sudebno-medicinskaya ocenka morfologii koloto-rezanyh ran, sformirovannyh
klinkami nozhej s razlichnymi defektami ostriya // Medicinskaya ekspertiza i
pravo.
2012. ¹ 1. P. 37-39.
3.
Krupin K.N., Vlasyuk I.V. Otobrazhenieekspluatacionnyhdefektovostriyakolyushche-rezhushchegoorudiya
v povrezhdeniyahkozhnogopokrova// Medicinskayaekspertiza i pravo. 2013. ¹ 2. P.
28-31.[in Russian]
4.
Kislov M.A., Leonov S.V. Ispol'zovanie metoda konechnyh elementov
dlya prognozirovaniya razrusheniya koloto-rezanyh povrezhdenij ploskih kostej//
Medicinskaya ekspertiza i pravo. 2016. ¹ 3. P. 22-24. [in Russian]
5.
Leonov S.V., Kislov M.A. Morfologicheskie osobennosti
koloto-rezanyh povrezhdenij reber pri vozdejstvii kolyushche-rezhushchim
predmetom vdol' kompakty// Medicinskaya ekspertiza i pravo. 2015. ¹ 3. P.
21-23. [in Russian]
6.
Zenkevich O. Metod konechnyh
elementov v tekhnike.
M: Mir 1975; 318. [in Russian]
7.
Leonov S.V., Pinchuk P.V.,
Krupin K.N., Panfilov D.A. The mathematical modeling of the injurious impact on
the tibial bone for the evaluation of the conditions leading to its fracture //
Forensic Medical Expertise.
2017. Volume. 60. ¹ 2. P.
11-13. https://doi.org/10.17116/sudmed201760211-13
8.
M. Milanowicz, K. Kedzior
Active numerical model of human body for reconstruction of falls from height //
Forensic Science International (2016).
http://dx.doi.org/10.1016/j.forsciint.2016.10.009
9.
Panfilov D.A., Romanchikov
V.V., Krupin K.N. Solving cross-disciplinary problems by mathematical modelling
// IOP Conference Series: Materials Science and Engineering.
2018. P. 022080. https://doi.org/10.1088/1757-899X/327/2/022080
10.
Pinchuk P.V., Krupin K.N.,
Petrov V.V., Leonov S.V. Specific fractures of the diaphysis of the femur
formed by a traumatic multicomponent bullet shot charge from a smoothbore
carbine "saiga 12k" at a distance in focus, visualization and
theoretical study of the fragment formation mechanism about them // Scientific
Visualization.
2018. Volume. 10. ¹ 2. P.
15-28https://doi.org/10.26583/sv.10.2.02
11.
Terzini, M., Aldieri, A.,
Nurisso, S., De Nisco, G., Bignardi, C. Finite Element Modeling Application in
Forensic Practice: A Periprosthetic Femoral Fracture Case Study // Frontiers in
Bioengineering and Biotechnology Volume 8, 23 June 2020, 619 DOI:
10.3389/fbioe.2020.00619
12.
H. Muggenthaler, M. Hubig, A.
Meierhofer. G. Mall Slip and tilt: modeling falls over railings //
International Journal of Legal Medicine volume 135, pages245–251 (2021)
https://doi.org/10.1007/s00414-020-02432-8
13.
Kislov M.A. Morfologiya I
mekhanika razrusheniya kostnoj tkani pod dejstviem kolyushche-rezhushchih
orudij: dissertaciya ... doktora Medicinskih nauk: 14.03.05 // Kislov Maksim
Aleksandrovich; - Moskva, 2016.-
241 p. [in
Russian]
14.
Leonov S.V., Vlasiuk I.V.,
Krupin K.N. Simulation of the mechanisms of formation of stab and slash wounds
by the finite element method // Forensic Medical Expertise.
2013. volume. 56. ¹ 6. P. 14-16.
15.
Krupin K.N. Current
application possibility of mathematical modeling using the finite element
method in forensic medicine//Vestnik medicinskogo instituta "REAVIZ":
reabilitaciya, vrach i zdorov'e.
2017. ¹ 6
(30). P. 127-132.
16.
Leonov S.V., Kislov M.A. The
morphology of the profile flat bones with stab injuries / Medicinskaya
ekspertiza i pravo.
2015. ¹ 4. P. 10-11.
17.
ANSYS®
EXPLICIT
DYNAMICS 2020, Release 2
https://www.ansys.com/
18.
Structural steel fatigue data
at zero mean stress, ASME BPV Code, Section 8, Div 2, Table 5-110.1, (1998).
19.
Martin, R. B. Skeletal Tissue
Mechanics / R. B. Martin, D. B. Burr, N. A. Sharkey. – New-York : Springer,
1998. – P. 347.